1. Cleanroom Classes
Cleanroom cleanliness is classified primarily according to ISO 14644-1. The classification considers the concentration of airborne particles whose diameter is equal to or greater than a specified size. A lower ISO number indicates a cleaner environment.
Maximum permitted concentration of particles ≥ 0.5 µm
| ISO class | Particles ≥ 0.5 µm per m3 | Approx. former US class |
| ISO 3 | 35 | Class 1 |
| ISO 4 | 352 | Class 10 |
| ISO 5 | 3,520 | Class 100 |
| ISO 6 | 35,200 | Class 1,000 |
| ISO 7 | 352,000 | Class 10,000 |
| ISO 8 | 3,520,000 | Class 100,000 |
The formerly common designations Class 1, Class 10 and Class 100 originate from the withdrawn US standard FED-STD-209E and referred to particle counts per cubic foot. Therefore, Class 1 is not the same as ISO 1: with respect to the concentration of particles 0.5 µm and larger, Class 1 corresponds approximately to ISO 3.
The ISO classification can also be determined for different operating states of a cleanroom: for the completed but empty room, for an operational room without personnel, and for the actual production state. A cleanroom class must therefore always be considered together with the conditions under which it was measured.